Welcome: Wenzhou Kangmu Co.,Ltd.
Home      NEWS     Company news       Electronic Human Tracheal Intubation Tra…

Company news

Electronic Human Tracheal Intubation Training Model KM/3

I. Product features:

This model human body modeling realistic, training operation with a strong sense of clinical. The electrical circuit is safe and reliable, the sensor has high sensitivity, and sound, light and electricity are combined.

Second, the product function:

1 tracheal intubation through the mouth.

2、 Observe and compare the normal pupil on one side and the dilated pupil on the other side.

3 indicating the puncture site of cricothyroid membrane.

II. Method of use:

1 The operator stands on the side of the head of the model. Tilt the head back 80 degrees, so that the mouth, pharynx and trachea basically overlap a line, and open the mouth.

2Hold the pharyngoscope in the left hand at a right angle to the larynx. Follow the back of the tongue into the oral cavity, to the root of the tongue, slightly lift the laryngoscope, see the edge of the epiglottis, the anterior end of the laryngoscope in the epiglottis and the root of the tongue, and then lift the laryngoscope, you can see the vocal folds.

3Hold the tracheal tube in the right hand and insert it into the vocal folds, inserting it through the vocal folds for about 1cm, the controller will flash green with a beautiful music. Quickly remove the catheter core, and then continue to rotate the catheter into the trachea 3-4cm.

4、 If the red light of the controller flashes and a “beep” sound is heard, it will indicate that the catheter is mistakenly inserted into the esophagus, and it should be quickly dialed out and reinserted.

5、 Plug a dental cushion next to the tracheal tube, exit the laryngoscope, and use adhesive tape to properly fix the catheter and dental cushion.

6、 Inject the appropriate amount of air into the catheter sleeve with a syringe. If there is no automatic balloon valve at the end of the balloon tube, use pliers to close it.

7、 Connect the respirator to the outer end of the catheter, squeeze the balloon and observe the lung expansion.

IV. the human tracheal intubation training model function:

1、 The tongue of the model is elastic and can be pressed down, and the epiglottis can be closer to the clinical reality with the activities of the tongue root, which is convenient for exposing the vocal folds.

2、 The movable jaw and neck joints make the operator feel realistically.

3、 The sensor correctly measures the position of intubation. The controller uses sound and light to notify the trainer of the correct or incorrect operation.

4. Normal and dilated pupils are available for teaching.

V. Scope of application: This model is suitable for students of medical and nursing colleges and universities, junior clinical health care personnel, all kinds of on-site first-aid personnel training, teaching demonstration of tracheal intubation techniques through the oral cavity and internship operations.

Maintenance and warranty:

1、 Please operate the model according to the use method. After use, scrub it clean and place it in a dry place.

2the model should be avoided from sunlight and exposure to prevent the human body from changing shape and fading.

3not familiar with the structure of the model, please do not disassemble, to prevent component damage.

4the human body leather jacket pollution, gauze or cotton dipped in diluted detergent wipe.

5 the model working voltage: 200-24V.

Note: If the regional voltage is unstable, please use voltage stabilization measures.