Child CPR Simulator KM/CPR170

Main Functional Characteristics
The product adopts the American Heart Association (AHA) 2015 international cardiopulmonary resuscitation (CPR) & cardiovascular first aid (ECC) guideline standards, the first to develop a new economic sixth-generation products specifically designed for the popularization of social cardiopulmonary resuscitation and medical school, health care system training, its shape is more perfect, more powerful, more convenient operation of the leading products.
Implementation standard: American Heart Association (AHA) 2015 international cardiopulmonary resuscitation (CPR) & emergency cardiovascular care (ECC) guidelines standards
Main Functions:
Simulates standard airway opening;
Manual finger position chest compression display alarm:
- Indicator light display for correct and wrong compression position and alarm for error;
- Pressure intensity correct, wrong indicator display and wrong alarm;
Manual mouth-to-mouth respiration (blowing) display alarm:
- The tidal volume blown in is less than 150 ml-200 ml < indicator display and alarm;
- The tidal volume blown in is between 150 ml and 200 ml and the correct indicator is displayed;
- Blowing into the tidal volume too fast or oversized, resulting in gas into the stomach indicator light display and alarm;
Operation frequency: the new international standard: 100-120 times / min
Operation mode: training operation;
Check the brachial artery response: hand cupping pressure leather ball, simulating brachial artery pulsation;
Working condition: using 220V power supply, after regulator voltage regulator output power 6V.
Material features: face skin, neck skin, chest skin, hair, the use of imported thermoplastic elastomer mixed rubber material, made of stainless steel mold by injection molding machine high temperature injection and pressure, with a clear anatomical signs, feel real, skin color uniformity, realistic shape, beautiful appearance, durable, disinfection and cleaning is not deformed, folded in half to replace the convenience of the same level of its materials abroad.


Advanced child CPR Manikin
---- instructions for use
I. Simulator installation process
First of all, the simulator upper body and lower limb parts from the suitcase, in the simulator hip side draw a leg fixed pin, the two lower limbs were inserted into the correct position of the buttocks and make the buttock hole is located in the thigh holes aligned, will be fixed pin from the hip side inserted and through the two lower limbs from the buttocks on the other side of the fixed, so that the simulation of the simulator installation is complete.
The resuscitation operation pad spread out, the simulator lying back on the operation pad, the simulator and the electronic display for the power line connection, and then the 220V, 500Ma/6V external voltage regulator from the suitcase out of the connection with the electronic display, and then plug the external power regulator into the 220V power supply, that is, to complete the process of all the wiring.
Second, the operation process, must master the standardized action and precautions:
1, the airway open - will simulate a person lying down on his back, operation, the operator of a hand two fingers pinch the nose, the other hand into the back of the neck or chin will be lifted up the head back and the horizontal plane to form a 70 degrees - 90 degrees.
2, correct, wrong artificial blowing function tips - first (1) find the correct position that is the lower middle third of the sternum junction (i.e., the two nipple line and the chest in the middle of the crosshairs) for the correct compression zone, the operator crosses the hands folded together or with the root of the palm of one hand, the arm is perpendicular to the simulated human chest compression zone, chest compression. The information feedback of wrong pressing position is digitally displayed by the yellow light. (2) Pressing intensity: the correct depth of chest compression is 5 centimeters, and the information feedback of the correct depth of compression is digitally displayed by the green light. If the correct depth of chest compressions is greater than 5 cm, the information feedback of the wrong depth of compressions is displayed by the red digital light. Perform artificial mouth-to-mouth blowing (such as the actual scene of rescue in some patients with closed mouth, upper and lower teeth clenched, can not be mouth-to-mouth blowing, you can take the mouth-to-nose blowing, and the simulator's mouth is open, such as the operation of the mouth-to-nose blowing, you must use your hand to seal the simulator's mouth and then mouth-to-nose blowing operation). (1) Correct blowing blowing into the tidal volume reaches about 150-200 ml per kg/8 ml, and the information feedback of the correct blowing volume on the monitor is shown by a green light. (2) Wrong blowing into the tidal volume for more than 200 ml, the information feedback of blowing too much air is digitally displayed by the yellow light. Error blowing too fast, in 0.2 seconds time to blow into the tidal volume is greater than 200 ml, the error of blowing too fast information feedback by the red light digital display. (3) Correct and incorrect manual compression function prompts-
Fourth, the operation mode
1, training exercises: this operation is to allow beginners to familiarize themselves with the basic essentials of the operation. Trainees do a good job before the operation of the various functions set, after the start, the first airway open. Then, the first mouth-to-mouth blowing or first chest compression can be operated correctly, the error of various types of functional indicator display and error alarm sound prompts.
2, single training or double training: this operation is the trainee in the training and practicing skilled conditions, according to the 2015 international cardiopulmonary resuscitation (CPR) & cardiovascular first aid (ECC) guide standard requirements of the spirit. Single operation training or assessment according to the latest standards of chest compression and artificial respiration ratio is always 30:2 requirements. First, perform 30 effective manual chest compressions. Then, in accordance with the frequency of 100-120 times / minute cue beat tone, the correct mouth-to-mouth blowing 2 times, 5 consecutive cycles of CPR cycle, that is, to complete the international rescue standard 30:2 requirements.
Maintenance:
1, the simulator is sterilized after use, such as face skin, mouth and nose, chest skin, respiratory tubes, towards the air valve, etc. Available cleaning solution scrub, disinfection.
2, face skin broken, need to be replaced again, first pull out the two sides of the ear pistil within the fixed pins, unload the old face skin, according to the original replacement of the new face skin, adjusted to restore the original. Lung air bag rupture need to be replaced, you can open the chest skin, the lung air bag above the cushion skin also sensor blowing the nail cap of the pull rod out, remove the cushion skin, the lung air bag structure, according to the same kind of replacement on the new lung air bag structure assembly, restoration of the original state.
3, the simulator and the computer monitor, placed in a ventilated dry place, can not be stored in the humid or sun-exposed places, in order to prevent the impact of the service life.
Precautions:
1, do mouth-to-mouth artificial respiration, must use disposable CPR training mask, one person a piece, in order to prevent cross-infection.
2, the operator's hands should be clean, women please wipe off lipstick and lipstick, to prevent dirty face skin and chest skin, not to mention the original ballpoint pen or other color pens scribble.
3, press operation, must be according to the rhythm of the work frequency, can not be chaotic press a burst, so as to avoid program disorders, such as program disorders, immediately turn off the main power switch, re-open, in order to prevent the impact of the service life of the computer monitor.