Electronic half-body CPR training simulator KM/CPR15200
The product combines the 2020 international CPR standard, the product function is fully upgraded, realize the pupil change, manual carotid artery pulsation, airway opening and other necessary conditions for the success of cardiopulmonary resuscitation, widely used in the major cardiopulmonary resuscitation training institutions, hospitals, medical schools and other units.
Functional features:
Standard analog airway opening display, when the airway is open, the airway green light is on.
Full operation timing function, operation process can be a key to reset to start the next round of operation, the whole voice prompts, volume can be adjusted at will, in the process of operation can be a key to mute, the whole digital counting, the number of times that the compression blowing is correct and incorrect.
Manual hand position chest compression display and alarm:
Indicator light display and voice alarm for correct and incorrect compression position, with compression rebound voice prompt.
The correct depth of compression (5-6CM) is shown by columnar green light; when the depth of compression is deeper than 6CM, columnar red light is shown and voice alarm “too big”; when the depth of compression is not deep enough and less than 5CM, columnar yellow light is shown and voice alarm “insufficient”. And rebound insufficient voice alarm.
Artificial respiration (blowing) display alarm:
Blowing tidal volume 500-1000ml correct and incorrect indicator light display, and voice alarm.
Blowing tidal volume greater than or equal to 500ml green column light display; blowing tidal volume less than 500ml column yellow light display, and voice alarm insufficient; blowing tidal volume greater than 1000ml column red light display, and voice alarm too large, when blowing tidal volume is too fast or oversized, resulting in the gas into the stomach red indicator light display and voice alarm.
Operation cycle:
Pressure and manual blowing 30:2 (single or double), complete 5 cycle cycle CPR operation.
Operation frequency:
New international standard: 100-120 times/minute
Operation mode:
Training operation mode
Check pupil reflection:
Comparative recognition of pupils by one dilated versus one constricted.
Check carotid artery reflection:
Hand cupping a pressure ball of skin to simulate carotid artery pulsation.
Material characteristics:
Face skin, neck skin, chest skin, hair, the use of imported thermoplastic elastomer mixed rubber material, by the stainless steel feelers, injection molding machine high temperature injection and become, with accurate anatomical signs, feel real, skin color uniformity, realistic shape, beautiful appearance, durable, disinfection and cleaning is not deformed, easy to dismantle and replace the characteristics of its materials to reach the same level abroad.
Simulator electronic display guide
1、Power switch: Select the power supply mode of this machine; select the battery power supply mode when the battery is selected, and select the power supply mode when the power supply is the self-belonged regulator power supply mode of this machine.
2、Start key: Press “Start” to enter the working state when it enters the working state at the end.
3、Reset key: when entering the working state, press the “reset” key can be a key to reset from a new start.
4, volume key and mute key, work volume adjustment, and mute selection.
5, press too small indicator: in the working state, when the pressure is less than 50mm, the yellow indicator light.
6, press the normal indicator: in the working state, when the pressure is greater than 50mm when the green indicator light.
7, press too large indicator: in the working state, when the pressure is greater than 60mm when the red indicator light.
8, blowing too small indicator: in the working state, when blowing less than 500ml when the yellow indicator light.
9, blowing normal indicator: in the working state, when blowing more than 500ml less than 1000ml when the green indicator light.
10, blowing too large indicator: in the working state, when blowing more than 1000ml when the red indicator light.
11、Airway indicator: When blowing operation, the green indicator light will be on when the airway is opened before blowing operation can be carried out.
12、Pressing position indicator: When pressing operation is carried out, the indicator light is green when the pressing position is correct, and red when the pressing position is wrong.
13, blowing into the stomach indicator: when the blowing operation, blowing too fast or the measurement is greater than 70ml above or blowing too fast when the red indicator light shows.