Welcome: Wenzhou Kangmu Co.,Ltd.
Home      PRODUCTS     Emergency Training Manikin     Full body CPR manikin       KM/CPR300S-H Full automatic computer CPR
  • KM/CPR300S-H Full automatic computer CPR manikin(CPR and Nursing)

KM/CPR300S-H Full automatic computer CPR manikin(CPR and Nursing)

  • Product Model : KM/CPR300S-H
  • Category: Full body CPR manikin
  • Item: KMA024
  • RMB Price: 14500
  • Product description:CPR300S-H Full automatic computer CPR manikin(CPR and Nursing)
  • INQUIRY   EMAIL

Executive standard: American heart association (AHA) 2015 international guidelines for cardiopulmonary resuscitation (CPR)

cardiovascular first aid (ECC).

CPR Manikin Function:

1). The pupil adopts the LCD screen to simulate the state of pupil narrowing, normal and dilation. Under the state of rescue, the pupil dilated and the pupil narrowed and restored to light emission after rescue.

2). The joints of the simulated human upper limbs can mave freely. (Before and after spin,stretch,stretch,spin in,spin out) The wrist and elbow joints can be flexion and extension. Can practice patient handling.

3). Equipment fault self-test function: after starting the machine, the equipment will automatically enter the self-test progren to check whether the equipment has faults.

4). The key operation adopts fault-tolerant technology.

5). The chest cage is newly added to detect insufficient rebound.

Manikin vital signs:

1). Initial state: No pulsating carotid artery, simulating dilated pupil.

2). In the process of pressing; Manikin carotid artery passive pulsation, pulse frequency and compression frequency consistent.

3). After successful rescue; Carotid artery beating autonomously, simulating pupil constriction and recovery of light reflex.

Standard airway can be opened and the airway indicator light is on.

Artificial hand chest compressions and artificial respiration can be performed.

Manual chest compressions:

1. Dynamic barcode indicator shows the depth of compression: the correct depth of compression (5-6cm area) is displayed by the green bar code, the depth of compression is not enough (less than 5cm) is shown by the yellow bar code, and the depth of compression is too deep (more than 6cm) is shown by the dynamic feedback of the movement of the red bar code indicator.

2. LCD count and frequency display; Keep detailed records of the specific reasons for wrong pressing (too much pressing force too little pressing force, wrong pressing position, too fast pressing frequency, too slow pressing frequency, etc.)

Artificial mouth-to-mouth breathing (blowing):

1. The dynamic bar code indicator displays the tidal volume: the tidal volume blown in is correct (500ml~600ml-1000ml), and the tidal volume blown in is too small or too large, and the tidal volume moved by the bar code yellow or red indicator respectively.

2. Liquid crystal counting display: the specific causes of air blowing errors are recorded in detail (according to excessive air blowing volume, air blowing into the stomach, air blowing force is too small, and the number of correct air blowing).

Ratio of compressions to breaths: 30:2 (single or double).

Operating cycle: 30 effective compressions and 2 manual blows, 30:2 5-cycle CPR.

Three operation methods: CPR training, simulation test and practical test.

CPR display function:

Electronic monitoring: electronic monitoring of airway opening and compression site, showing correct and incorrect number of artificial respiration and cardiac compressions.

The operating time can be set in seconds.

Operating frequency: 100-120 times/min.

Operation time: in seconds.

Check pupils: narrow and contrast.

Power status: 220V power supply is adopted, and 12V power supply is output after the voltage is stabilized by the stabilizer.

Printer functions:

You can select the printing process after the end of the operation.

Two types of short and long printing, short printing records the results of pressing and blowing in the whole operation process, comprehensive judgment and score; Long print overlay short print on the basis of showing pressure and blow waveforms.

The controller is equipped with lithium battery and need no be connected to 220V power supply.

New electronic remote control function: teachers can remote control CPR start, stop, reset, mode selection, pupil change,

carotid pulse, printer and other functions by remote control.

Nursing functions:

1. The simulated person can lie on the back and bend the knee, support the legs independently after abduction, and rotate the

upper arms and legs flexibly.

2. Holistic care: bath on the bed, wear change clothes, cold, heat therapy.

3. Arm intravenous injection and blood transfusion training.

4. Subcutaneous deltoid injection.

5. Intramuscular injection of buttocks and thighs.

6. Male and female catheterization.

7. Nursing of fistula and drainage.

INQUIRY